Model 422LP9R 

Port-Powered RS-232 to 

RS-422 Converter

  

 

 
 
 
 

 

 
The 422LP9R is a port-powered two-channel RS-232 to RS-422 converter. It converts TD and RD RS-232 lines to 
balanced RS-422 signals. The unit is powered from the RS-232 handshake lines DTR and RTS. One of these 
handshake lines must be asserted (high) in order to power the unit (See Table 1). The RS-422 driver is enabled when 
RTS is asserted. Therefore, RTS must be asserted in order to transmit data. The RS-422 receiver is always enabled. If 
DTR is always asserted and the RTS is used to control the driver, the 422LP9R can be used as a RS-232 to RS-485 4-
wire converter. To insure reception, it is recommended that DTR is asserted. 
 
In order to maximize the amount of power available to the RS-422 driver, the RS-232 

handshake lines are not looped 

back 

(tied together). As a result the following handshake lines will appear as disasserted (low):  CTS, DCD, and DSR. 

Care should be taken to insure that any software being used doesn’t require any of these handshake lines be asserted. 
If existing software requires any of the handshake lines to be asserted, you can loop back the required handshake lines 
in your cable. 

 

 

Table 1 

 

* NOTE:  Low = disasserted and High = asserted 

 
Connections 

The 422LP9R can be connected in three different type of systems:  RS-422 (Figure 1), four-wire RS-485 (Figure 1), and 
two-wire RS-485 (Figure 2). Regardless of the system, the 422LP9R must be connected with the proper polarity.  With 
no data is being sent and the driver enabled, the RS-232 line should be negative and the TD(A) should be negative with 
respect to TD(B). Proper operation of any RS-422 system requires the presence of a signal return path between the 
signal grounds of the equipment at each end of an interconnection.  This circuit reference may be established by a third 
conductor connecting the common leads of devices, or it may be provided by connections in each piece of equipment to 
an earth reference. When the circuit reference is provided by a third conductor, the connection between the signal 
grounds and the third conductor should contain some resistance (e.g. 100 ohms) to limit circulating currents when other 
ground connections are provided for safety. 
 

 

RTS State

 

DTR State

 

Functions Possible

 

(when port powering unit) 

Low 

Low 

none 

Low 

High 

Receive 

High 

Low 

Transmit, Receive 

High 

High 

Transmit, Receive 