Function Code
Name
Setting Range
Factory Default
Value
available
unavailable
F92.36
Segment display of digital output status
0
~
1FH (segment display)
0
The status of the nixie tube in right end of the operation panel shows the output status of digital value. In
order to describe clearly, we defined each section of nixie tube in the operation panel as follows:
A
G
F
D
C
E
B
marker of
nixie tube
segment
meaning of “shining” of
nixie tube segment
meaning of “not-shining”
of nixie tube segment
A
Signal output of
terminal Y1
No signal output of
terminal Y1
B
Signal output of
terminal Y2
No signal output of
terminal Y2
C
Relay 1 is on
Relay 1 is off
D
Relay 2 is on
Relay 2 is off
E
Relay 3 is on
Relay 3 is off
F92.37
Present Floor
0
~
F20.00
1
This parameter Can view the current floor of the car (Can range control mode).
F92.38
High-byte of present location
0
~
255 (unit:65.535m)
0
F92.39
Low-byte of present location
0
~
65.535m
0
This parameter Can view the current floor of the car (Can range control mode). Current position = current
position high *65.535+ current position low (m).
F92.40
Mark of shaft self-learning successfully.
0: no learning
1: lerning successfully
2: learning failed
0
This parameter can be used to see whether the current elevator has been shaft self-learning and whether
self-learning successfully.
6.22 Factory Parameters (Group F99)
Function Code
Name
Setting Range
Factory Default
Value
F99.00
Factory password input
00000
~
65535
Factory setting
The rest parameters in this group will be shown only after the correct password is entered.