KATANA S610M Inverter Specialized for Elevator Manual
Terminal
Symbol
T
Meaning
B+
Encoder differential frequency dividing output B+/OC output
phase B
A-
Encoder differential frequency dividing output A-
B-
Encoder differential frequency dividing output B-
GND
Common port of frequency dividing output
7.3.2 Parameters setting
The setting of common function codes under terminal analog operation mode is shown in table 7-5, while
setting of special function codes is shown in table 7-6.
Table 7-5 Setting of common function codes under terminal analog operation mode
Function code
Name
Recommend set value
Remarks
F00.01
Control mode
selection
Set according to the
actual situation
F00.04
Rated speed of
elevator
Set according to the
actual situation
F00.07
Maximum output
frequency
Set according to the
actual situation
F01.00
Rated power of the
motor
Set according to the
actual situation
Motor nameplate parameter
F01.01
Rated voltage of the
motor
Set according to the
actual situation
F01.02
Rated current of the
motor
Set according to the
actual situation
F01.03
Rated frequency of
the motor
Set according to the
actual situation
F01.04
Rated speed of the
motor
Set according to the
actual situation
F06.00
zero-speed start P
200
Adjust according to practical
operation effect
F06.01
zero-speed start I
100
F06.02
ASR1-P
20.0
F06.03
ASR1-I
0.200
F06.04
ASR1 output filter
0
F06.05
ASR2-P
20.0
F06.06
ASR2-I
0.200
F06.07
ASR2 output filter
0
F06.08
ASR1/2 switch
frequency
10%
F06.09
None-zero speed
torque limit value
180%