26
KATANA S610M Inverter Specialized for Elevator Manual
1: Iran Mode (utilize magnetic
bean)
Note: In China Mode, only need to
use parameters of Group F22 to
compensate the leveling; In Iran
Mode, need to use parameters of
Group F22 and F23 to compensate
the leveling.
F20.19
Speed of slight motion
leveling
0.03~0.10
0.01m/s
0.05
×
F20.20
Speed
of
door
pre-opening
0.00~0.50
0.01m/s
0.30
×
Group F21 CAN Communication Distance Control Parameters 2
F21.00
Length
of
leveling
plugin plate
10~800
1mm
300
×
F21.01
Delay
starting
of
Bottom floor interval
of hoistway tuning.
1.0~20.0
0.1S
2.0
×
F21.02
Height difference of
upward first class
forced
deceleration
switch.
-10.000~10.000
0.001m
0
*
F21.03
Height difference of
upward second class
forced
deceleration
switch.
-10.000~10.000
0.001m
00.000
*
F21.04
Height difference of
upward
third
class
forced
deceleration
switch.
-10.000~10.000
0.001m
00.000
*
F21.05
Height difference of
downward first class
forced
deceleration
switch.
-10.000~10.000
0.001m
00.000
*
F21.06
Height difference of
downward second class
forced
deceleration
switch.
-10.000~10.000
0.001m
00.000
*
F21.07
Height difference of
downward third class
forced
deceleration
switch.
-10.000~10.000
0.001m
00.000
*
F21.08
Switch-on
time
of
leveling switch
0~200ms
1ms
2
×
F21.09
Disposition method of
the first-class forced
exchange
0~1
1
0
×
F21.10
Interval
of
double-leveling
photo-switch
0~600
1mm
300
×
F21.11
Height
of
upward 00.000~60.000
0.001m
00.000
×