KATANA S610M Inverter Specialized for Elevator Manual
It refers to the average acceleration and deceleration of the elevator during acceleration and deceleration.
F20.08
Inspection Speed
(F20.11) ~0.63 m/s
0.30
F20.09
Acceleration time of inspection
0.1~3.0s
1.0
F20.10
Deceleration time of inspection
0.1~2.0s
0.3
F20.11
Runing speed of none car fast termination
0.05~Min (0.20, F20.08)
m/s
0.10
Inspection Speed refers to elevator running speed under inspection status.
Acceleration time of inspection refers to the time when elevator accelerates from 0-speed to F20.09 under inspection
status.
Deceleration time of inspection refers to the time when elevator decelerates from F20.0 to 0-speed under inspection
status.
Runing speed of none car fast termination refers to the running speed of the elevator when it meets the first level
forced deceleration switch at the end station under inspection or termination correction status.
Curve is showed as below:
Figure 6-13 Curve of inspection operation don’t meet terminal station
Figure 6-14 Curve of inspection operation meet terminal station