81
KATANA S610M Inverter Specialized for Elevator Manual
Others
Reserved
Attentions:
1.
E007 is not detected by inverters of 380V and below 176A, but can be detected by other models.
2.
E010 can only be reset 10 seconds after it occurred.
3.
If overcurrent occurs, it needs 6 seconds delay to reset.
4.
Axxx will be displayed on the keyboard when error alert starts (e.g. when contactor error occurs, E018 will be
displayed on the keyboard if error protection acts, while A018 will be displayed if operation continues with
warning.
6.20 Inverter Parameters (Group F91)
Function Code
Name
Setting Range
Factory Default
Value
F91.00
Serial number
0000
~
FFFF
7109
F91.01
Software version No.
0.00
~
99.99
2.01.06
F91.02
Customized version No.
0
~
99.99
1.00
F91.03
Temporary Version No.
00.000
~
64.999
Factory setting
F91.04
Rated capacity
0.0
~
999.9KVA
Factory setting
F91.05
Rated voltage
0
~
999V
Factory setting
F91.06
Rated current
0.0
~
299.9A
Factory setting
Parameters in this group are inherent parameters of the inverter, which cannot be modified by users.
6.21 Status Display Parameters (Group F92)
Function Code
Name
Setting Range
Factory Default
Value
F92.00
Given speed
-10.000~10.000m/s
0.000
This parameter is for monitoring the given speed of the inverter, including speed direction.
F92.01
Instruction speed (after integrator)
-10.000~10.000m/s
0.000
This parameter is for monitoring the output speed of the inverter, including speed direction, after
acceleration/deceleration process.
F92.02
Feedback speed
-10.000~10.000m/s
0.000
This is the actual elevator speed acquired by the encoder under closed-loop vector control.
F92.03
The set frequency
-100.00
~
100.00Hz
0.00
This parameter is for monitoring the set frequency of the inverter. If the frequency is positive, the motor
is operating forward; if it is negative, the motor is operating in reverse.
F92.04
Instruction frequency (after
integrator)
-100.00
~
100.00Hz
0.0