KATANA S610M Inverter Specialized for Elevator Manual
4.1.4 Function code check and operation description
Operation flow for two-level menus: the operation panel parameters setting adopt two-level menus for quick and
convenient check and modification on parameters.
The two level menus are: function codes (primary menu), and set value of function codes (secondary menu).
Figure 4-4 Operation flow diagram for two-level menus
Explanation:
Press key “PRG” or “ENTER” to return to the primary menu from the secondary menu. The
difference between “ENTER” and “PRG” is: when “ENTER” is pressed, the parameter setting is saved before the
operation panel display is back to the primary menu moving to the next function code automatically; when “PRG”
is pressed, the operation panel display is directly back to the primary menu remaining at the current function code
without saving the parameter setting.
Note: in the above figure, the displayed shutdown parameter is the set frequency. The factory default value is
50.00Hz. The bold underlined part refers to the blinking unit.
4.1.5 Operation examples
Example 1: To modify the rated speed of the motor
To modify the function code F01.05 from 1440RPM to 1439RPM is shown as below:
Figure 4-5 Example for modifying the rated speed of the motor
Example 2: To restore to the factory default setting
Set F13.03=2 to restore the parameter to the factory default setting, which is shown as below:
PRG
>>
ENTER
ENTER
50.00
F00.0