25
KATANA S610M Inverter Specialized for Elevator Manual
(flashing)
LED thousands digit
:
BIT0
:
Bus voltage
BIT1
:
Operating speed
(R/MIN)
BIT2
:
The set speed (R/MIN)
(flashing)
Note:
The
set
frequency
is
displayed by default when the
inverter is shutdown, while output
frequency is displayed by default
during operation, if the above are
all set to zero.
Group F20 CAN Communication Distance Control Parameters 1
F20.00
Floors quantity
2~64
1
2
×
F20.01
Present floor setting
0: No action
Set present floor as 1~F20.00
1
0
×
F20.02
Run speed
0.100
~
F00.04
0.001m/s
1.500m/s
×
F20.03
Start frequency under
fast running mode
0.00~5.00
0.01Hz
0
×
F20.04
Terrace of fast starting
0.00~Min (1.00, F20.02)
0.01Hz
0
×
F20.05
Terrace starting delay
0~10
5ms
2
×
F20.06
Delay time of staring
under low speed
0.00~5.00
0.01s
0
×
F20.07
Average
acceleration/deceleratio
n speed
0.10~2.00
0.01
m/s2
0.30
×
F20.08
Inspection Speed
(F20.11) ~0.63
0.01m/s
0.30
×
F20.09
Inspection acceleration
time
0.1~3.0
0.1s
1.0
×
F20.10
Inspection deceleration
time
0.1~2.0
0.1s
0.3
×
F20.11
Operation speed of non
fast running terminal
station.
0.05~Min(0.20,F20.08)
0.01m/s
0.10
×
F20.12
Search leveling speed
of
non
terminal
station.
0.05~0.30
0.01m/s
0.20
×
F20.13
Speed
of
hoistway
self-tuning
0.10~0.50
0.01m/s
0.30
×
F20.14
Security diagnosis of
elevator
0: prohibit
1: start security diagnosis
1
0
×
F20.15
Class
of
forced
deceleration switch
1~3
1
1
×
F20.16
Instal
quantity
of
leveling switch
0:1 piece
1:2 pieces
1
0
×
F20.17
Time adjustment of S
curve
0~90
1%
56
×
F20.18
Leveling switch mode
0: China Mode (utilize magnetic
shielding plate)
1
1
×