KATANA S610M Inverter Specialized for Elevator Manual
Function Code
Name
Setting Range
Factory Default
Value
LED tens digit: Power on and Auto-tuning selection of synchronous motor.
0:Start power on and auto-tuning of synchronous motor.
1:Forbid power on and auto-tuning of synchronous motor.
LED hundreds digit: Power-on and tuning selection of larger deviation CD angle
0: Turn on tuning
1: Prohibit tuning
LED thousands digit: Cancel mode selection of torque slope when stopping.
0: No PI mode
1: PI mode
F09.04
Motor overload protection selection
0
~
2
2
0: no action
There would be no overload protection for the motor (select with caution!).
1: general motor (with low-speed compensation)
The heat dissipation effect of general motor is weakened when the motor operates at low speed, so the
corresponding electronic thermal protection value needs to be adjusted accordingly. The low speed
compensation refers to decrease of overload protection threshold for the motor whose operating frequency is
lower than 30Hz.
2: variable-frequency motor (without low-speed compensation)
Because the heat dissipation of variable-frequency motor is not affected by speed, there is no need to
adjust the protection value at low speed.
F09.05
Selection 1 of special error screening.
0
~
1111H
0
LED units digit: CD error screening selection of sincos Encoder.
LED tens digit: AB low-speed error screening selection of sincos Encoder.
LED hundreds digit: Z pulse error screening selection of Encoder.
LED thousands digit: Car uncontrolled error screening selection
0: unshielded, warn error and stopping.
1: shielded
F09.06
Selection 2 of special error screening.
0
~
1111H
0
LED units digit: Basic pole sealing error screening selection
LED tens digit: CAN communication error screening selection
LED hundreds digit: Magnetic pole tuning error shielding selection
LED thousands digit: Reserved
0: unshielded, warn error and stopping.
1: shielded
F09.07
Error locking selection
0
~
1
0
0: error locking prohibited
1: error locking permitted, which means it can redisplay the error that exits when the last time the system is
powered off, and the error must be reset before resuming normal operation.
Note:Undervoltage couldn’t be as an error to lock when inverter power-on next time.
F09.08
Manufacturer debugging parameter
F09.08 are manufacturer debugging parameters