F07.10
Terminal filtering time
0
~
500
1ms
10
○
F07.11
Input
terminal
activeness setting
Binary setting:
0: positive logic, active under
conducting state
1: negative logic, active under off
state
LED units digit
:
BIT0
~
BIT3
:
X1
~
X4
LED tens digit
:
BIT0
~
BIT3
:
X5
~
X8
LED hundreds digit
:
BIT0
~
BIT1
:
X9~X10
1
000
○
F07.12
Functions(Y1) of open
collector output
0
:
Non functional
1: inverter running signals
2: frequency arrival signals
3: frequency level detection signals
(FDT1)
4: frequency level detection signals
(FDT2)
5: the inverter is ready for operation
6: stopping the inverter caused by
undervoltage
7: inverter failure
8: up signal output
9: down signal output
10: in zero-speed operation
11: braking control output
12: operating contactor control
output
13: signal of Motor Brake enables
to open
14: Direction signal of light-load
15: Output of pre-open door
16: Braking power output
17: Basic pole block error output
(E030)
Other
:
reserved
1
0
×
F07.13
Functions(Y2) of open
collector output
Same as Y1
1
0
×
F07.14
Relay 1 output
Same as Y1
1
13
×
F07.15
Relay 2 output
Same as Y1
1
10
×
F07.16
Relay 3 output
Same as Y1
1
7
×
F07.17
Reserved
F07.18
Output
terminal
activeness setting
Binary setting:
0: active under conducting state
1: active under off state
LED units digit:
BIT0
~
BIT3
:
Y1, Y2, relay 1,
relay 2
LED tens digit:
BIT0: relay 3
1
0
○