82
KATANA S610M Inverter Specialized for Elevator Manual
Function Code
Name
Setting Range
Factory Default
Value
This parameter is for monitoring the output frequency of the inverter, including frequency direction,
after acceleration/deceleration process.
F92.05
Output frequency
-100.0
~
100.0Hz
0.00
This parameter is for monitoring the output frequency including its direction.
F92.06
Output voltage
0
~
800V
0
This parameter is for monitoring the output voltage of the inverter.
F92.07
Output current
0.0
~
3Ie
0.0
This parameter is for monitoring the output current of the inverter.
F92.08
Torque current
-300.0%
~
300.0%
0.0
This parameter is the torque current of the inverter as a percentage of the rated current of the motor.
F92.09
Flux current
0.0%
~
100.0%
0.0
This parameter is the flux current as a percentage of the rated current of the motor.
F92.10
Power of the motor
0.0%
~
200.0%
0.0
This parameter is the output power of the inverter as a percentage of the rated power of the motor.
F92.11
Estimated frequency of the motor
-100.0
~
100.0Hz
0.00
This is an estimated frequency of the rotor under open-loop vector control.
F92.12
Actual frequency of the motor
-100.0
~
100.0Hz
0.00
This is the actual frequency of the rotor acquired by the encoder under closed-loop vector control.
F92.13
Bus voltage
0
~
800V
0
This parameter is for monitoring bus voltage of the inverter.
F92.14
Operating status of the inverter
0000
~
FFFFH
0000