7-8
Guaranteed term
The guaranteed term is for one year from after the receipt of the product to the customer, but against the
magnetron refers to below.
Part name
Type/code
Guaranteed term
Magnetron
MAF1562R /
5VMAA00116
for 4000 hours
Magnetron guarantee condition :
Only for the radar has sensitivity remarkable decrease, another case is without guaranteed term.
Exchange standard of a regular change parts
In this radar there are parts that recommend a regular exchange. Before the parts are increasingly consumed and
don't work, the exchange is recommended.
A standard exchange interval of each part is as follows.
Remark ) 1. The life of parts changes by the using system environment.
2. The following standard exchange interval is not guaranteed value.
Part name
Standard exchange
interval
Type/code
The occurrence of phenomenon
when parts were consumed
Scanner Motor
20000 hours
CBP-202 /
CBP-202
Allophone generation and
rotation stop.
Fan motor in
NDC-1774
40000 hours
109R0812H4D01 /
5BFAB00687
Shortening the service life of the
circuit in control unit.
Backup battery in
CDC-1513
5 years
CR2032 /
5ZBCJ00012
Stopping of built in clock in the
radar process circuit.
The radar performance decreases though the parts can work even if the following parts pass the exchange
standard interval.
Part name
Standard exchange
interval
Type/code
The occurrence of phenomenon
when parts were consumed
Magnetron
12 months
( Available time of
average is from about
6000 to 8,000hours.)
MAF1562R /
5VMAA00116
The radar sensitivity
decreases, and it becomes
difficult to take the tune.
Important information
㸸
When the product is used under the following environments, the parts life time might
become remarkably short.
Part name
Environment of the product using
Scanner Motor
Vibration of radar mast more than product standard.
Or continuous driving under strong wind.
Fan motor in
NDC-1774
Installation of process unit(NDC-1774) to space that becomes high
temperature sealed.
Summary of Contents for JMR-611
Page 2: ......
Page 24: ......
Page 26: ......
Page 28: ......
Page 33: ...1 5 1 1 4 EXTERIOR DRAWINGS y Fig 1 1 Exterior Drawing of Scanner Unit Type NKE 387 Unit mm...
Page 34: ...1 6 Fig 1 2 Exterior Drawing of Processing Unit Type NDC 1774 Unit mm...
Page 35: ...1 7 1 1 4 EXTERIOR DRAWINGS y Fig 1 3 Exterior Drawing of Operating Unit Type NCE 5923 Unit mm...
Page 38: ......
Page 54: ......
Page 116: ......
Page 118: ......
Page 124: ......
Page 134: ......
Page 136: ......
Page 142: ......
Page 144: ......
Page 154: ......
Page 156: ......
Page 160: ......
Page 164: ......
Page 166: ......
Page 172: ......
Page 174: ......
Page 177: ...APPENDIX Fig 1 Block Diagram of JMR 611...
Page 181: ...APPENDIX Fig 5 Internal Connection Diagram of Control Unit NCM 994...
Page 182: ......
Page 184: ......
Page 186: ......
Page 187: ......