Chapter 5:
Console Operation
Input Channels
:
DYNAMIC
114/ 380
V1.0/1
Eclipse User Guide
DYNAMIC
On input channels there are two sections of dynamics
processing: a noise gate and a compressor.
The DYNAMIC panel has 3 buttons and 5 rotary controls, which
may be switched between the gate and compressor sections
using the
Gate/Comp.
button. The front panel also includes
metering for:
•
IN
– input level to the dynamics.
•
GATE
– gate activity.
•
Red.
– gain reduction applied by the compressor.
•
OUT
– output level from the dynamics.
The front panel controls follow the on-screen layout shown on
the Main Mix display. So, for example, when adjusting the
compressor, the top controls adjust
Attack
time and
Threshold
, the middle controls are
Release
time and make up
Gai
n, and the lower control sets the
Ratio
:
The Main Mix display includes the same
IN
,
GATE
,
Red.
and
OUT
metering as the front panel. Note that the red and yellow
markers on the input level meter represent the gate and
compressor thresholds:
This area also includes a dynamics curve which shows the sum
of both sections of processing: Gating plus Compression.