289
Appendix A: Event code tables
Event code: 202
Message:
Power supply thermal failure.
Severity:
Major.
Explanation:
The thermal sensor associated with a power supply indicates an overheat condition that shut down the power
supply. The second power supply assumes the full operating load for the director.
Action:
Replace the failed power supply. Perform the data collection procedure and return the CD and failed power
supply to IBM support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Event code: 203
Message:
Power supply AC voltage recovery.
Severity:
Informational.
Explanation:
AC voltage recovered for the power supply. Both power supplies adjust to share operating load for the director.
Action:
No action required.
Event Data:
No supplementary data included with the event.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Summary of Contents for TotalStorage SAN140M
Page 2: ......
Page 14: ...SAN140M Installation and Service Manual xii...
Page 16: ...SAN140M Installation and Service Manual xiv...
Page 54: ...SAN140M Installation and Service Manual 22...
Page 186: ...SAN140M Installation and Service Manual 154...
Page 240: ...SAN140M Installation and Service Manual 208...
Page 282: ...SAN140M Installation and Service Manual 250...
Page 294: ...SAN140M Installation and Service Manual 262...
Page 366: ...SAN140M Installation and Service Manual 334...
Page 370: ...SAN140M Installation and Service Manual 338...
Page 378: ...SAN140M Installation and Service Manual 346...
Page 424: ...SAN140M Installation and Service Manual 392...
Page 427: ......
Page 428: ...Printed in USA GC26 7664 04...