117
Chapter 3: Maintenance analysis procedures (MAPS)
c. Ensure Ethernet cables are not damaged. If damaged, replace the
cables.
Was the maintenance action successful?
NO
YES
↓
The management server connection is restored. Exit MAP.
9
Does the configuration use multiple daisy-chained Ethernet hubs?
YES
NO
↓
Go to
step 11
.
10
Verify hubs are correctly daisy-chained.
a. Top hub - Ensure an RJ-45 Ethernet cable connects to port 24 and
the medium-dependent interface (MDI) switch is set to MDI (in)
(
Figure 48
(1)).
b. Middle hub - Ensure the cable from the top hub connects to port
12,
the cable from the bottom hub connects to port 24, and the
MDI switch is set to MDI (in) (
Figure 48
(2)).
c. Bottom hub - Ensure the cable from the middle hub connects to
port 12 and the MDI switch is set to MDIX (out) (
Figure 48
(3)).
Figure 48
Daisy-chained Ethernet hubs
i140M015
1
2
3
Summary of Contents for TotalStorage SAN140M
Page 2: ......
Page 14: ...SAN140M Installation and Service Manual xii...
Page 16: ...SAN140M Installation and Service Manual xiv...
Page 54: ...SAN140M Installation and Service Manual 22...
Page 186: ...SAN140M Installation and Service Manual 154...
Page 240: ...SAN140M Installation and Service Manual 208...
Page 282: ...SAN140M Installation and Service Manual 250...
Page 294: ...SAN140M Installation and Service Manual 262...
Page 366: ...SAN140M Installation and Service Manual 334...
Page 370: ...SAN140M Installation and Service Manual 338...
Page 378: ...SAN140M Installation and Service Manual 346...
Page 424: ...SAN140M Installation and Service Manual 392...
Page 427: ......
Page 428: ...Printed in USA GC26 7664 04...