SAN140M Installation and Service Manual
110
MAP 0200: POST failure analysis
This MAP describes fault isolation for power-on self-test (POST)
failure. The failure indicator are event codes observed at the Event Log
(EFCM Basic Edition or Element Manager interface).
1
Table 10
lists event codes, explanations, and MAP steps.
2
POST/IPL diagnostics detected a FRU failure.
a. At the Event Log, examine the first two bytes (0 and 1) of event
data.
b. Byte 0 indicates the failed component. Byte 1 is the slot number
of the failed FRU (00 for a nonredundant FRU, 00 or 01 for
redundant FRUs, and 00 through 34 for port cards.
Table 11
lists byte 0 FRU codes and associated steps that describe
fault isolation procedures.
Table 10
MAP 200 event codes
Event
code
Explanation
Action
400
Power-up diagnostic failure.
Go to
step 2
.
411
Firmware fault.
Go to
step 9
.
413
Backup CTP card POST failure.
Go to
step 10
.
Table 11
MAP 200: byte 0 FRU codes
Byte 0
Failed FRU
Action
01
Backplane.
Go to
step 3
.
02
CTP card.
Go to
step 4
.
03
SBAR assembly.
Go to
step 5
.
05
Fan module.
Go to
step 6
.
06
Power supply.
Go to
step 7
.
08 - 0F
Port card.
Go to
step 8
.
Summary of Contents for TotalStorage SAN140M
Page 2: ......
Page 14: ...SAN140M Installation and Service Manual xii...
Page 16: ...SAN140M Installation and Service Manual xiv...
Page 54: ...SAN140M Installation and Service Manual 22...
Page 186: ...SAN140M Installation and Service Manual 154...
Page 240: ...SAN140M Installation and Service Manual 208...
Page 282: ...SAN140M Installation and Service Manual 250...
Page 294: ...SAN140M Installation and Service Manual 262...
Page 366: ...SAN140M Installation and Service Manual 334...
Page 370: ...SAN140M Installation and Service Manual 338...
Page 378: ...SAN140M Installation and Service Manual 346...
Page 424: ...SAN140M Installation and Service Manual 392...
Page 427: ......
Page 428: ...Printed in USA GC26 7664 04...