274
Event code: 072
Message:
E_Port connected to unsupported switch.
Severity:
Informational.
Explanation:
The director is attached (through an ISL) to an incompatible fabric element (director or switch).
Action:
Disconnect the ISL.
Event Data:
No supplementary data included with this event.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Event code: 073
Message:
Fabric initialization error.
Severity:
Informational.
Explanation:
An error was detected during the fabric initialization sequence, most likely caused by frame delivery errors. Event
data is intended for engineering evaluation.
Action:
Perform the data collection procedure and return the CD to IBM support personnel.
Event Data:
Byte 0 = error reason code for engineering evaluation.
Bytes 4 - 9 = port numbers for which problems were detected.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Summary of Contents for TotalStorage SAN140M
Page 2: ......
Page 14: ...SAN140M Installation and Service Manual xii...
Page 16: ...SAN140M Installation and Service Manual xiv...
Page 54: ...SAN140M Installation and Service Manual 22...
Page 186: ...SAN140M Installation and Service Manual 154...
Page 240: ...SAN140M Installation and Service Manual 208...
Page 282: ...SAN140M Installation and Service Manual 250...
Page 294: ...SAN140M Installation and Service Manual 262...
Page 366: ...SAN140M Installation and Service Manual 334...
Page 370: ...SAN140M Installation and Service Manual 338...
Page 378: ...SAN140M Installation and Service Manual 346...
Page 424: ...SAN140M Installation and Service Manual 392...
Page 427: ......
Page 428: ...Printed in USA GC26 7664 04...