SAN140M Installation and Service Manual
82
•
An attention indicator (yellow triangle) associated with a port at
the Hardware View, Port List View, or Port Properties dialog box.
•
Data recorded in the Threshold Alert Log.
To configure threshold alerts:
1. Select Threshold Alerts from the Configure menu at any view. The
Configure Threshold Alert(s) dialog box displays. If alerts are
configured, they display in table format showing the alert name,
type, and state.
2. Click New. The New Threshold Alert dialog box (screen 1) displays
(
Figure 43
).
Figure 43
New threshold alert dialog box (Screen 1)
3. Type a name (64 alphanumeric characters or less) in the Threshold
Alert Name field.
4. Select from the Threshold Alert drop-down list to configure the
alert type. Available selections are:
• Receive - An alert occurs if the threshold value for receive
throughput is reached or exceeded.
• Transmit - An alert occurs if the threshold value for transmit
throughput is reached or exceeded.
• Receive and Transmit - An alert occurs if the threshold value
for either throughput is reached or exceeded.
5. Click Next. The New Threshold Alert dialog box (screen 2) displays
(
Figure 44
).
2
4M1
17
6
Summary of Contents for TotalStorage SAN140M
Page 2: ......
Page 14: ...SAN140M Installation and Service Manual xii...
Page 16: ...SAN140M Installation and Service Manual xiv...
Page 54: ...SAN140M Installation and Service Manual 22...
Page 186: ...SAN140M Installation and Service Manual 154...
Page 240: ...SAN140M Installation and Service Manual 208...
Page 282: ...SAN140M Installation and Service Manual 250...
Page 294: ...SAN140M Installation and Service Manual 262...
Page 366: ...SAN140M Installation and Service Manual 334...
Page 370: ...SAN140M Installation and Service Manual 338...
Page 378: ...SAN140M Installation and Service Manual 346...
Page 424: ...SAN140M Installation and Service Manual 392...
Page 427: ......
Page 428: ...Printed in USA GC26 7664 04...