SAN140M Installation and Service Manual
326
Event code: 607
Message:
Director contains no operational SBARs.
Severity:
Severe.
Explanation:
The director firmware does not recognize an installed SBAR.
Action:
Install at least one functional SBAR and power-on reset (POR) the director.
Event Data:
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Event code: 608
Message:
User initiated SBAR switch-over.
Severity:
Informational.
Explanation:
The backup SBAR has become the active SBAR at a user’s request. The previously active SBAR is now the
backup SBAR.
Action:
No action required.
Event Data:
There is no supplementary data included with this event.
Distribution:
Director
Management Server
Host
Nonvolatile
System
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Summary of Contents for TotalStorage SAN140M
Page 2: ......
Page 14: ...SAN140M Installation and Service Manual xii...
Page 16: ...SAN140M Installation and Service Manual xiv...
Page 54: ...SAN140M Installation and Service Manual 22...
Page 186: ...SAN140M Installation and Service Manual 154...
Page 240: ...SAN140M Installation and Service Manual 208...
Page 282: ...SAN140M Installation and Service Manual 250...
Page 294: ...SAN140M Installation and Service Manual 262...
Page 366: ...SAN140M Installation and Service Manual 334...
Page 370: ...SAN140M Installation and Service Manual 338...
Page 378: ...SAN140M Installation and Service Manual 346...
Page 424: ...SAN140M Installation and Service Manual 392...
Page 427: ......
Page 428: ...Printed in USA GC26 7664 04...