Chapter 3: Maintenance analysis procedures (MAPS)
7
An SBAR assembly is not recognized by director firmware because
the firmware version is not supported or the SBAR assembly failed.
Advise the customer of the problem and determine the correct
firmware version to download.
Download the firmware (
Download and install firmware
on page 195).
Perform a data collection after the download (
Collecting maintenance
data
on page 186).
Did the firmware download solve the problem?
NO
YES
↓
The director appears operational. Exit MAP.
8
Visual inspection (amber LED is lit) or event codes indicate an SBAR
assembly failed.
Replace the SBAR assembly (
RRP: SBAR assembly
on page 241).
• The procedure is concurrent and performed while the product is
operational.
• Perform a data collection as part of FRU replacement (
Collecting
maintenance data
on page 186).
Was the maintenance action successful?
YES
NO
↓
Contact the next level of support. Exit MAP.
The product is operational. Exit MAP.
Summary of Contents for TotalStorage SAN140M
Page 2: ......
Page 14: ...SAN140M Installation and Service Manual xii...
Page 16: ...SAN140M Installation and Service Manual xiv...
Page 54: ...SAN140M Installation and Service Manual 22...
Page 186: ...SAN140M Installation and Service Manual 154...
Page 240: ...SAN140M Installation and Service Manual 208...
Page 282: ...SAN140M Installation and Service Manual 250...
Page 294: ...SAN140M Installation and Service Manual 262...
Page 366: ...SAN140M Installation and Service Manual 334...
Page 370: ...SAN140M Installation and Service Manual 338...
Page 378: ...SAN140M Installation and Service Manual 346...
Page 424: ...SAN140M Installation and Service Manual 392...
Page 427: ......
Page 428: ...Printed in USA GC26 7664 04...