107
Chapter 3: Maintenance analysis procedures
Was the maintenance action successful?
NO
YES
↓
The product is operational.
Exit MAP.
6
Verify power supply operation.
a. Inspect each power supply to determine if the amber failure LED
is illuminated.
b. If an amber LED is illuminated, ensure the indicated power
supply is correctly installed and seated. Partially remove and
reseat the power supply. Refer to
Field-replaceable unit:
Redundant power supply
.
Was the maintenance action successful?
NO
YES
↓
The product is operational.
Exit MAP.
A power supply failure is indicated.
Go to
step 3
.
MAP 0200: POST failure analysis
This MAP describes fault isolation for a POST failure. The failure
indicator is event code
400
or
411
observed at the
Event Log
(EFCM
Basic Edition or Element Manager interface).
1
Table 9
lists event codes, explanations, and MAP steps.
Table 9
MAP 200 Event Codes
Event
code
Explanation
Action
400
Power-up diagnostic failure.
Go to
step 2
.
411
Firmware fault.
Go to
step 4
.
Summary of Contents for SAN32M-2
Page 2: ......
Page 10: ...SAN32M 2 Installation and Service Manual xii...
Page 14: ...SAN32M 2 Installation and Service Manual xvi...
Page 42: ...SAN32M 2 Installation and Service Manual 16...
Page 120: ...SAN32M 2 Installation and Service Manual 94...
Page 174: ...SAN32M 2 Installation and Service Manual 148...
Page 236: ...SAN32M 2 Installation and Service Manual 210...
Page 240: ...SAN32M 2 Installation and Service Manual 214...
Page 244: ...SAN32M 2 Installation and Service Manual 218...
Page 290: ...SAN32M 2 Installation and Service Manual 264...
Page 308: ...SAN32M 2 Installation and Service Manual 282...
Page 311: ......
Page 312: ...Printed in USA GC26 7763 01...