SAN32M-2 Installation and Service Manual
234
Event code: 141
Message:
Congestion relieved on an ISL.
Severity:
Informational.
Explanation:
OpenTrunking firmware detected an ISL with Fibre Channel traffic that previously exceeded the configured
congestion threshold. The congestion is now relieved.
Action:
No action required.
Event data:
Byte
0
= Port number reporting congestion relieved.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
Event code: 142
Message:
Low BB_Credit detected on an ISL.
Severity:
Informational.
Explanation:
OpenTrunking firmware detected an ISL with no transmission BB_Credit for a period of time that exceeded the
configured low BB_Credit threshold. This indicates downstream fabric congestion.
Action:
No action is required for an isolated event or if the reporting ISL approaches 100% throughput. If this event
persists, relieve the low BB_Credit condition by adding parallel ISLs, increasing the ISL link speed, or moving
device connections to a less-congested region of the fabric.
Event data:
Byte
0
= Port number reporting low BB_Credit.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
Summary of Contents for SAN32M-2
Page 2: ......
Page 10: ...SAN32M 2 Installation and Service Manual xii...
Page 14: ...SAN32M 2 Installation and Service Manual xvi...
Page 42: ...SAN32M 2 Installation and Service Manual 16...
Page 120: ...SAN32M 2 Installation and Service Manual 94...
Page 174: ...SAN32M 2 Installation and Service Manual 148...
Page 236: ...SAN32M 2 Installation and Service Manual 210...
Page 240: ...SAN32M 2 Installation and Service Manual 214...
Page 244: ...SAN32M 2 Installation and Service Manual 218...
Page 290: ...SAN32M 2 Installation and Service Manual 264...
Page 308: ...SAN32M 2 Installation and Service Manual 282...
Page 311: ......
Page 312: ...Printed in USA GC26 7763 01...