SAN32M-2 Installation and Service Manual
112
8
Transmit or receive errors for the Ethernet adapter exceeded a
threshold, the link was not connected, or the link timed out. A problem
with the Ethernet cable, Ethernet hub(s), or other LAN-attached
device is indicated. Verify the product is connected to the
management server through one or more Ethernet hubs:
a. Ensure an RJ-45 Ethernet cable connects the product to a hub.
If not, connect the cable as directed by the customer.
b. Ensure an RJ-45 Ethernet cable connects the management
server to a hub. If not, connect the cable as directed by the
customer.
c. Ensure Ethernet cables are not damaged. If damaged, replace
the cables.
Was the maintenance action successful?
NO
YES
↓
The management server connection is restored.
Exit MAP.
9
Does the configuration use multiple daisy-chained Ethernet hubs?
YES
NO
↓
Go to
step 11
.
Table 11
MAP 300 error messages
Error message
Action
Never connected.
Go to
step 8
.
Link timeout.
Go to
step 8
.
Protocol mismatch.
Go to
step 15
.
Duplicate session.
Go to
step 18
.
Unknown network address.
Go to
step 21
.
Incorrect product type.
Go to
step 23
.
Summary of Contents for SAN32M-2
Page 2: ......
Page 10: ...SAN32M 2 Installation and Service Manual xii...
Page 14: ...SAN32M 2 Installation and Service Manual xvi...
Page 42: ...SAN32M 2 Installation and Service Manual 16...
Page 120: ...SAN32M 2 Installation and Service Manual 94...
Page 174: ...SAN32M 2 Installation and Service Manual 148...
Page 236: ...SAN32M 2 Installation and Service Manual 210...
Page 240: ...SAN32M 2 Installation and Service Manual 214...
Page 244: ...SAN32M 2 Installation and Service Manual 218...
Page 290: ...SAN32M 2 Installation and Service Manual 264...
Page 308: ...SAN32M 2 Installation and Service Manual 282...
Page 311: ......
Page 312: ...Printed in USA GC26 7763 01...