105
Chapter 3: Maintenance analysis procedures
MAP 0100: Power distribution analysis
This MAP describes fault isolation for the product power distribution
system, including defective AC power cords or redundant power
supplies. One or more of the following indicate a failure:
•
Failure of the product to power on.
•
Event code
200
or
201
observed at the
Event Log
(EFCM Basic
Edition or Element Manager interface).
1
Ensure the product is connected to facility power. Inspect the product
for indications of being powered on, such as:
•
An illuminated
PWR
LED (green) or
ERR
LED (amber).
•
Illuminated LEDs adjacent to Fibre Channel ports.
•
Noise and airflow from cooling fans.
Is the product powered on?
YES
NO
↓
A power distribution problem is indicated.
Go to
step 4
.
2
Table 8
lists event codes, explanations, and MAP steps.
3
As indicated by visual inspection or event code
200
or
201
, one or
both power supplies failed and must be removed and replaced. Refer
to
Field-replaceable unit: Redundant power supply
.
•
The procedure is concurrent and performed while the product is
operational.
Table 8
MAP 100 event codes
Event
code
Explanation
Action
200
Power supply AC voltage failure.
Go to
step 3
.
201
Power supply DC voltage failure.
Go to
step 3
.
Summary of Contents for SAN32M-2
Page 2: ......
Page 10: ...SAN32M 2 Installation and Service Manual xii...
Page 14: ...SAN32M 2 Installation and Service Manual xvi...
Page 42: ...SAN32M 2 Installation and Service Manual 16...
Page 120: ...SAN32M 2 Installation and Service Manual 94...
Page 174: ...SAN32M 2 Installation and Service Manual 148...
Page 236: ...SAN32M 2 Installation and Service Manual 210...
Page 240: ...SAN32M 2 Installation and Service Manual 214...
Page 244: ...SAN32M 2 Installation and Service Manual 218...
Page 290: ...SAN32M 2 Installation and Service Manual 264...
Page 308: ...SAN32M 2 Installation and Service Manual 282...
Page 311: ......
Page 312: ...Printed in USA GC26 7763 01...