135
Chapter 3: Maintenance analysis procedures
2
A minor error occurred that caused the Fabric Services database to
be re-initialized to an empty state, and a disruptive fabric logout and
login occurred for all attached devices. Indications are:
•
Event code 011 -
The Login Server database failed cyclic
redundancy check (CRC) validation.
•
Event code 021 -
The Name Server database failed CRC
validation.
Devices resume operation after fabric login. Perform a data collection
and contact the next level of support. Refer to
Collect maintenance
data
(EFCM Basic Edition) or
Collect maintenance data
(Element
Manager).
Exit MAP.
Table 17
MAP 600 event codes
Event
code
Explanation
Action
011
Login Server database invalid.
Go to
step 2
.
021
Name Server database invalid.
Go to
step 2
.
051
Management Server database invalid.
Go to
step 3
.
061
Fabric Controller database invalid.
Go to
step 4
.
062
Maximum interswitch hop count exceeded.
Go to
step 5
.
063
Remote switch has too many ISLs.
Go to
step 6
.
070
E_Port is segmented.
Go to
step 7
.
071
Switch is isolated.
Go to
step 7
.
072
E_Port connected to unsupported switch.
Go to
step 15
.
082
Port fenced.
Go to
step 16
.
140
Congestion detected on an ISL.
Go to
step 21
.
142
Low BB_Credit detected on an ISL.
Go to
step 21
.
150
Fabric merge failure.
Go to
step 22
.
Summary of Contents for SAN32M-2
Page 2: ......
Page 10: ...SAN32M 2 Installation and Service Manual xii...
Page 14: ...SAN32M 2 Installation and Service Manual xvi...
Page 42: ...SAN32M 2 Installation and Service Manual 16...
Page 120: ...SAN32M 2 Installation and Service Manual 94...
Page 174: ...SAN32M 2 Installation and Service Manual 148...
Page 236: ...SAN32M 2 Installation and Service Manual 210...
Page 240: ...SAN32M 2 Installation and Service Manual 214...
Page 244: ...SAN32M 2 Installation and Service Manual 218...
Page 290: ...SAN32M 2 Installation and Service Manual 264...
Page 308: ...SAN32M 2 Installation and Service Manual 282...
Page 311: ......