257
Appendix A: Event code tables
Event code: 516
Message:
Optical digital diagnostics alarm threshold exceeded.
Severity:
Minor.
Explanation:
An optical transceiver digital diagnostics alarm threshold was exceeded. Additional event code
516
events are
recorded if the problem persists.
Action:
Replace the transceiver.
Event data:
Byte
0
= port number.
Byte
2
= optic type.
Bytes
4
-
7
= elapsed millisecond tick count.
Bytes
8
-
31
= First, second, and third type (and threshold value) of warning threshold exceeded as follows:
01
= TX temperature,
02
= TX supply voltage,
03
= TX bias current,
04
= TX power,
05
= RX power.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
Event code: 523
Message:
FL_Port open request failed.
Severity:
Informational.
Explanation:
When the indicated FL_Port attempted to open a loop device, a port open (OPN) sequence was returned.
Action:
No action required.
Event data:
Byte
0
= port number.
Byte
1
= arbitrated loop physical address (AL_PA) of the device transmitting the OPN sequence.
Distribution:
Product
Management Server
Host
EFCM Basic
Event Log
System
Error LED
Event Log
Call-Home
Sense Info
Link Incident
Log
Summary of Contents for SAN32M-2
Page 2: ......
Page 10: ...SAN32M 2 Installation and Service Manual xii...
Page 14: ...SAN32M 2 Installation and Service Manual xvi...
Page 42: ...SAN32M 2 Installation and Service Manual 16...
Page 120: ...SAN32M 2 Installation and Service Manual 94...
Page 174: ...SAN32M 2 Installation and Service Manual 148...
Page 236: ...SAN32M 2 Installation and Service Manual 210...
Page 240: ...SAN32M 2 Installation and Service Manual 214...
Page 244: ...SAN32M 2 Installation and Service Manual 218...
Page 290: ...SAN32M 2 Installation and Service Manual 264...
Page 308: ...SAN32M 2 Installation and Service Manual 282...
Page 311: ......
Page 312: ...Printed in USA GC26 7763 01...