Chapter 5: Removal and replacement procedures
•
315 -
Cooling fan propeller recovered.
If the event codes do not appear, go to
MAP 0000: Start MAP
to
isolate the problem.
7. Verify power supply operation. At a web browser communicating
with the EFCM Basic Edition interface or at the management
server (Element Manager application), open the
Hardware View
and observe the FRU graphic to ensure alert symbols do not
appear (yellow triangle or red diamond).
If a problem is indicated, go to
MAP 0000: Start MAP
to isolate the
problem.
8. Perform the data collection procedure. Refer to
Collect maintenance
data
(EFCM Basic Edition) or
Collect maintenance data
(SAN
management application) for instructions.
9. Clear the system error LED on the product front bezel:
— At a web browser communicating with the EFCM Basic
Edition interface, select
Clear System Error Light
from the
Maintenance
menu.
— At the management server (Element Manager application),
open the
Hardware View
. Right-click the front panel bezel
graphic (away from a FRU), then click the
Clear System Error
Light
menu selection.
10. If necessary, close and lock the equipment cabinet door.
Summary of Contents for SAN32M-2
Page 2: ......
Page 10: ...SAN32M 2 Installation and Service Manual xii...
Page 14: ...SAN32M 2 Installation and Service Manual xvi...
Page 42: ...SAN32M 2 Installation and Service Manual 16...
Page 120: ...SAN32M 2 Installation and Service Manual 94...
Page 174: ...SAN32M 2 Installation and Service Manual 148...
Page 236: ...SAN32M 2 Installation and Service Manual 210...
Page 240: ...SAN32M 2 Installation and Service Manual 214...
Page 244: ...SAN32M 2 Installation and Service Manual 218...
Page 290: ...SAN32M 2 Installation and Service Manual 264...
Page 308: ...SAN32M 2 Installation and Service Manual 282...
Page 311: ......
Page 312: ...Printed in USA GC26 7763 01...