662
Pin states undefined
(Max. 100
µ
s)
3.3 V
1.7 V/1.8 V/1.9 V/2.0 V
3.3 V power
1.7 V/1.8 V/1.9 V/2.0 V power
RESETP
All other pins
*
Pin states undefined
Power-on reset state
,,,,
,,,,
Note:
*
Except power/GND, clock related, and analog pins
Power-On Sequence
•
Power-off order
1. In the reverse order of powering-on, first turn off the 1.7 V/1.8 V/1.9 V/2.0 V power, then
turn off the 3.3 V power within 100
µ
s. This interval should be as short as possible.
2. Pin states are undefined while only the 1.7 V/1.8 V/1.9 V/2.0 V power is off. The system
design must ensure that these undefined states do not cause erroneous system operation.
Summary of Contents for SH7709S