648
Table 22.2
H-UDI Commands
Bit 15 to 12
TI3
TI2
TI1
TI0
Description
0
0
0
0
EXTEST
0
1
0
0
SAMPLE/PRELOAD
0
1
0
1
Reserved
0
1
1
0
H-UDI reset negate
0
1
1
1
H-UDI reset assert
1
0
0
—
Reserved
1
0
1
—
H-UDI interrupt
1
1
0
—
Reserved
1
1
1
0
Reserved
1
1
1
1
Bypass mode
(Initial value)
0
0
0
1
Recovery from sleep
Bits 11 to 0—Reserved: These bits are always read as 1.
22.3.3
Boundary Scan Register (SDBSR)
The boundary scan register (SDBSR) is a shift register, located on the PAD, for controlling the
input/output pins of the SH7709S.
Using the EXTEST and SAMPLE/PRELOAD commands, a boundary scan test conforming to the
JTAG standard can be carried out. Table 22.3 shows the correspondence between the pins of this
LSI and boundary scan register bits.