416
13.2.3
Minute Counter (RMINCNT)
The minute counter (RMINCNT) is an 8-bit readable/writable register used for setting/counting in
the BCD-coded minute section of the RTC. The count operation is performed by a carry for each
minute of the second counter.
The range that can be set is 00–59 (decimal). Errant operation will result if any other value is set.
Carry out write processing after halting the count operation with the START bit in RCR2.
RMINCNT is not initialized by a power-on reset or manual reset, or in standby mode.
Bit:
7
6
5
4
3
2
1
0
—
10 minutes
1 minute
Initial value:
0
—
—
—
—
—
—
—
R/W:
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
13.2.4
Hour Counter (RHRCNT)
The hour counter (RHRCNT) is an 8-bit readable/writable register used for setting/counting in the
BCD-coded hour section of the RTC. The count operation is performed by a carry for each 1 hour
of the minute counter.
The range that can be set is 00
–
23 (decimal). Errant operation will result if any other value is set.
Carry out write processing after halting the count operation with the START bit in RCR2 or using
a carry flag as shown in figure 13.2.
RHRCNT is not initialized by a power-on reset or manual reset, or in standby mode.
Bit:
7
6
5
4
3
2
1
0
—
—
10 hours
1 hour
Initial value:
0
0
—
—
—
—
—
—
R/W:
R
R
R/W
R/W
R/W
R/W
R/W
R/W
Summary of Contents for SH7709S
Page 2: ...Hitachi SuperH RISC engine SH7709S Hardware Manual ADE 602 250 Rev 1 0 09 21 01 Hitachi Ltd ...
Page 75: ...56 ...
Page 107: ...88 ...
Page 125: ...106 ...
Page 139: ...120 ...
Page 203: ...184 ...
Page 245: ...226 ...
Page 411: ...392 ...
Page 609: ...590 ...
Page 635: ...616 ...
Page 663: ...644 ...
Page 679: ...660 ...