80
EM. GRND AB
ON
ON
Stop button on the ground is pressed
–
line A is closed and line B is
open
OFF
OFF
Stop button on the ground is released
–
line A is open and line B is
closed
EMRC GND AB
ON
ON
Stop button on the remote control ground connected on the ground is
pressed
–
lines A and B of the stop button are open
OFF
OFF
Stop button on the remote control ground connected on the ground is
released
–
lines A and B of the stop button are closed
EM.BASK.AB
ON
ON
The stop button on remote control is pressed
–
lines A and B of the
stop button are open
OFF
OFF
The stop button on remote control is released
–
lines A and B of the
stop button are closed
FOTO AB
ON
ON
Photocells are aligned with the reflector (machine is closed and aligned)
–
Photocell A contact is open and photocell B contact is closed
OFF
OFF
Photocells are not aligned with the reflector (machine is not closed and
aligned)
–
Photocell A contact is closed and photocell B contact is open
ST12 CLOSED
ON
Pressure switch of outriggers n.1 and n.2 closes the contact
–
the
outriggers are at end run and the max pressure valve is opened
OFF
Pressure switch contact of outriggers n.1 and n.2 is opened
–
the
outriggers are open, partially open or already closed
ST34 CLOSED
ON
Pressure switch of outriggers n.3 and n.4 closes the contact
–
the
outriggers are at end run and the max pressure valve is opened
OFF
Pressure switch contact of outriggers n.3 and n.4 is opened
–
the
outriggers are open, partially open or already closed
TEMP. ALRMA
Option
ON
Temperature external probe reached the maximum value, the
temperature probe is closed
OFF
Temperature external probe
hasn’t reached the maximum value,
the
temperature probe is open
Summary of Contents for LightLift 15.70 3S
Page 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Page 12: ...12 ...
Page 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Page 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Page 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Page 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Page 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Page 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Page 108: ...108 CELLS PACK WITHOUT COVER ...