82
MICROJIB AB
DOWN
DOWN
The JIB is closed
–
the control switch is released, line A is open and line
B is closed
UP
UP
The JIB is open
–
the control switch is pressed, line A is closed and line
B is open
PEDAL AB
ON
ON
The pedal is pressed
–
the pedal electric line A is open and line B is
closed
Option
OFF
OFF
The pedal is released
–
the pedal electric line A is closed and line B is
open
R.C. BASKET
ON
The remote control is in the support in basket
OFF
The remote control is not in the support in basket
TRACK OPEN A
ON
Left track is fully widened. Widening cylinder of left track contact is
closed
OFF
Left track is not fully widened. Widening cylinder of left track contact is
open
TRACK OPEN B
ON
Right track is fully widened. Widening cylinder of right track contact is
closed
OFF
Right track is not fully widened. Widening cylinder of right track contact
is open
INCLIN. X
0,05
Indicates the inclination of the machine on the X axis in degrees
INCLIN. Y
0,30
Indicates the inclination of the machine on the Y axis of degrees
LOAD AB
134
133
Indicates the weight of the basket (about 50 Kg) plus the weight into
the basket in Kg measured by A and B lines
POS. 3 ARM
2073
Indicates the opening of the 3rd boom cylinder in tenths of a millimetre
Summary of Contents for LightLift 15.70 3S
Page 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Page 12: ...12 ...
Page 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Page 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Page 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Page 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Page 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Page 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Page 108: ...108 CELLS PACK WITHOUT COVER ...