74
9.8
ELECTRIC MOTOR (NOT FOR LITHIUM VERSION)
Electric motor works only when the machine is connected to the electric network
(110÷230 V). To start the electric motor it is necessary to:
-
connect the 110÷230 V plug of the machine to the electric network
-
activate the circuit breaker
-
start the motor by pressing the electric motor start button (on the remote
control or at the ground control box) so that its contactor is closed
Electric motor runs always at minimum speed 1500 rpm, it is equipped with
two capacitors in order to limit the absorption during the motor starting.
POWER SUPLLY
PLUG
CIRCUIT BREAKER
BOX
ELECTRIC MOTOR
CIRCUIT
BRAKER
ELECTRIC MOTOR
CONTACTOR