24
When machine is not closed and
aligned, if operator try to move an
outrigger display will remind that
machine need to be closed and aligned
by the error message aside.
NOTE: If during the stabilization the photocells lose the signal, for example due
to movements in progress,
the “MACHINE CLOSED AND ALIGNED”
icon
disappears but the movements will continue for a while
even if signal doesn’t
come back.
4.2.1 AUTOMATIC STABILIZATION
To be able to automatically stabilize the machine it must be closed and aligned,
to automatically stabilize the machine it has to be press remote control button
n.7 “AUTO
-
STABILIZATION” and
keep it pressed until that
display shows “OK”.
AUTO-STABILIZATION procedure sets all the outriggers at the ground and
automatically levels the machine on both axles “X” and “Y”, w
hile the procedure
is in progress the display shows
“WAIT” and the outriggers conditions, as
indicated by the following example.
ERROR
“MACHINE
CLOSED AND
ALIGNED”
ICON
“
AUTO-STABILIZATION
”
BUTTON
PHOTOCELLS
REFLECTOR
Summary of Contents for LightLift 15.70 3S
Page 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Page 12: ...12 ...
Page 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Page 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Page 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Page 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Page 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Page 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Page 108: ...108 CELLS PACK WITHOUT COVER ...