57
8.4.2
DRIVE GEAR MOTORS
Each drive gear motors runs forward or backward independently, it’s so possible
to turn the machine. Drive gear motors are controlled by the ground
valveblocks and each one is equipped with an automatic brake that is
hydraulically deactivated only while it runs.
On the machine
equipped with “second speed”,
drive gear motors are equipped
with a second speed system, indeed they are variable capacity so that they can
perform two different hydraulic speeds in order to change tracks speeds further
that rpm regulation.
The second speed block contains the coil in charge to activate the second speed,
selecting HARE from remote control button the control module will energize
that coil.
When that coil is energized oil is sent to both drive gear motors to move their
plate so that their chamber capacity will be reduce.
With reduced capacity the gear rate is increased so that the tracks speed is
increased too.
SECOND SPEED
VALVE COIL
SECOND SPEED
PRESSURE GAUGE
AUTO2SPEED
PRESSURE
CALIBRATION
PLUG
Summary of Contents for LightLift 15.70 3S
Page 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Page 12: ...12 ...
Page 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Page 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Page 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Page 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Page 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Page 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Page 108: ...108 CELLS PACK WITHOUT COVER ...