132
APPENDIX 11
–
INPUT MENU OLDER THAN RELEASE 2.0
ST1 GND A
ON
Outrigger n.1 on the ground
–
the switch is released and A line is
closed
OFF
Outrigger n.1 lifted
–
the switch is pressed and A line is open
ST1 GND B
ON
Outrigger n.1 on the ground
–
the switch is released and B line is open
OFF
Outrigger n.1 lifted
–
the switch is pressed and B line is closed
ST2 GND A
ON
Outrigger n.2 on the ground
–
the switch is released and A line is
closed
OFF
Outrigger n.2 lifted
–
the switch is pressed and A line is opened
ST2 GND B
ON
Outrigger n.2 on the ground
–
the switch is released and B line is open
OFF
Outrigger n.2 lifted
–
the switch is pressed and B line is closed
ST3 GND A
ON
Outrigger n.3 on the ground
–
the switch is released and A line is
closed
OFF
Outrigger n.3 lifted
–
the switch is pressed and A line is opened
ST3 GND B
ON
Outrigger n.3 on the ground
–
the switch is released and B line is open
OFF
Outrigger n.3 lifted
–
the switch is pressed and B line is closed
ST4 GND A
ON
Outrigger n.4 on the ground
–
the switch is released and A line is
closed
OFF
Outrigger n.4 lifted
–
the switch is pressed and A line is opened
Summary of Contents for LightLift 15.70 3S
Page 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Page 12: ...12 ...
Page 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Page 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Page 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Page 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Page 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Page 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Page 108: ...108 CELLS PACK WITHOUT COVER ...