94
10.1.9.8.6.6
SKYGUARD
By this page
it’s possible to set the
Skyguard function, when
it is activated, by pressing on Skyguard bar it stops certain
movements, more details are indicated at APPENDIX 8.
After having inserted the relevant
password “4771”,
pressing button n.1 “ON”
and restarting by the main key it
will be activated, pressing button n.2 “OFF”
and restarting
by the main key it will be deactivated.
“REBOOT” indication means that the machine has to be
restarted by the main key to activate the function.
10.1.9.8.7
OPTIONAL (PAGE 3)
PAGE 3
The here aside picture shows the OPTIONAL menu third page
display.
Pressing button n.7 it’s possible to come back to the
second
page of settings.
Pressing button n.9 (ESC) brings back to the EXTRA menu.
10.1.9.8.7.1
CHG SET
For a lithium machine, by this
page it’s possible to set the
maximum charging current, after having inserted the
relevant password “1138”, pressing button
n.1 it will be
settled 25 Amp, pressing button n.2 it will be settled 18 Amp.
This setting, considering the transformation rate, has to
respect the maximum current available on local electric plug.
10.1.9.8.7.2
INV SET
For a lithium machine, b
y this page it’s possible to set
up the
rpm setting for a new inverter, pressing button n.1 the rpm
setting will be settled according to the machine model settled
by the relevant menu, check chapter 10.1.9.2.
NOTE: Some pages are not accessible, or could not show same information, if
not after having inserted the relevant password.
Hinowa is able to check which password have been inserted and when.
SKYGUARD
85
1 ON
86
87
2 OFF *
REBOOT
88
9 ESC
OPTIONAL
89
1 CHG SET
90
2 INV SET
91
7 PREV.
92
8 NEXT
93
9 ESC
CHG SETUP
94
1 STANDARD
95
2 1,2 KW
25
96
9 ESC
INV SETUP
97
1 SETUP
98
9 ESC
Summary of Contents for LightLift 15.70 3S
Page 1: ...1 TECHNICAL COURSE BOOKLET LightLift 15 70 3S PERFORMANCE TTLL1570021702 ...
Page 12: ...12 ...
Page 13: ...13 2 4 LL15 70 WORKING AREA 230 KG UNRESTRICTED CAPACITY ...
Page 45: ...45 7 4 1 GASOLINE HONDA iGX390 EMERGENCY START ...
Page 46: ...46 7 4 2 DIESEL HATZ 1B40 EMERGENCY START ...
Page 49: ...49 8 2 HYDRAULIC DIAGRAM 8 2 1 HYDRAULIC DIAGRAM INDEX ...
Page 50: ...50 8 2 2 PUMPS AND UNDERCARRIAGE PART HYDRAULIC DIAGRAM TO THE AERIAL PART VALVEBLOCK ...
Page 51: ...51 8 2 3 AERIAL PART HYDRAULIC DIAGRAM FROM THE DEVIATOR VALVE ...
Page 108: ...108 CELLS PACK WITHOUT COVER ...