GE Multilin
G60 Generator Protection System
A-3
APPENDIX A
A.1 PARAMETER LISTS
A
6289
SRC 3 In Mag
Amps
Source 3 neutral current magnitude
6291
SRC 3 In Angle
Degrees
Source 3 neutral current angle
6292
SRC 3 Ig RMS
Amps
Source 3 ground current RMS
6294
SRC 3 Ig Mag
Amps
Source 3 ground current magnitude
6296
SRC 3 Ig Angle
Degrees
Source 3 ground current angle
6297
SRC 3 I_0 Mag
Amps
Source 3 zero-sequence current magnitude
6299
SRC 3 I_0 Angle
Degrees
Source 3 zero-sequence current angle
6300
SRC 3 I_1 Mag
Amps
Source 3 positive-sequence current magnitude
6302
SRC 3 I_1 Angle
Degrees
Source 3 positive-sequence current angle
6303
SRC 3 I_2 Mag
Amps
Source 3 negative-sequence current magnitude
6305
SRC 3 I_2 Angle
Degrees
Source 3 negative-sequence current angle
6306
SRC 3 Igd Mag
Amps
Source 3 differential ground current magnitude
6308
SRC 3 Igd Angle
Degrees
Source 3 differential ground current angle
6336
SRC 4 Ia RMS
Amps
Source 4 phase A current RMS
6338
SRC 4 Ib RMS
Amps
Source 4 phase B current RMS
6340
SRC 4 Ic RMS
Amps
Source 4 phase C current RMS
6342
SRC 4 In RMS
Amps
Source 4 neutral current RMS
6344
SRC 4 Ia Mag
Amps
Source 4 phase A current magnitude
6346
SRC 4 Ia Angle
Degrees
Source 4 phase A current angle
6347
SRC 4 Ib Mag
Amps
Source 4 phase B current magnitude
6349
SRC 4 Ib Angle
Degrees
Source 4 phase B current angle
6350
SRC 4 Ic Mag
Amps
Source 4 phase C current magnitude
6352
SRC 4 Ic Angle
Degrees
Source 4 phase C current angle
6353
SRC 4 In Mag
Amps
Source 4 neutral current magnitude
6355
SRC 4 In Angle
Degrees
Source 4 neutral current angle
6356
SRC 4 Ig RMS
Amps
Source 4 ground current RMS
6358
SRC 4 Ig Mag
Amps
Source 4 ground current magnitude
6360
SRC 4 Ig Angle
Degrees
Source 4 ground current angle
6361
SRC 4 I_0 Mag
Amps
Source 4 zero-sequence current magnitude
6363
SRC 4 I_0 Angle
Degrees
Source 4 zero-sequence current angle
6364
SRC 4 I_1 Mag
Amps
Source 4 positive-sequence current magnitude
6366
SRC 4 I_1 Angle
Degrees
Source 4 positive-sequence current angle
6367
SRC 4 I_2 Mag
Amps
Source 4 negative-sequence current magnitude
6369
SRC 4 I_2 Angle
Degrees
Source 4 negative-sequence current angle
6370
SRC 4 Igd Mag
Amps
Source 4 differential ground current magnitude
6372
SRC 4 Igd Angle
Degrees
Source 4 differential ground current angle
6656
SRC 1 Vag RMS
Volts
Source 1 phase AG voltage RMS
6658
SRC 1 Vbg RMS
Volts
Source 1 phase BG voltage RMS
6660
SRC 1 Vcg RMS
Volts
Source 1 phase CG voltage RMS
6662
SRC 1 Vag Mag
Volts
Source 1 phase AG voltage magnitude
6664
SRC 1 Vag Angle
Degrees
Source 1 phase AG voltage angle
6665
SRC 1 Vbg Mag
Volts
Source 1 phase BG voltage magnitude
6667
SRC 1 Vbg Angle
Degrees
Source 1 phase BG voltage angle
6668
SRC 1 Vcg Mag
Volts
Source 1 phase CG voltage magnitude
6670
SRC 1 Vcg Angle
Degrees
Source 1 phase CG voltage angle
6671
SRC 1 Vab RMS
Volts
Source 1 phase AB voltage RMS
6673
SRC 1 Vbc RMS
Volts
Source 1 phase BC voltage RMS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 3 of 27)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for Multilin g60
Page 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Page 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...