G-4
G60 Generator Protection System
GE Multilin
G.1 CHANGE NOTES
APPENDIX G
G
3-24
3-24
Update
Deleted references to COM 1 RS485 port in section 3.2.9 CPU Communication Ports. Revised
text and Figure 3-25 CPU Module Communications Wiring to include only modules T, U, V in
section 3.2.9a.
5-1
5-1
Update
Updated the front panel main menu to include the CyberSentry security menu
5-15
5-15
Update
Update Communications main menu to remove the SNTP Protocol submenu
5-15
5-15
Delete
Deleted references to COM 1 RS485 port in section 5.2.4b Serial Ports
5-16
5-16
Add
Added section 5.2.4c Ethernet Network Topology
5-17
5-17
Update
Updated Networks section 5.2.4d to include all three Ethernet ports
5-17
5-17
Update
Added 0 as valid number to section 5.2.4e Modbus Protocol section
5-40
5-
Delete
Deleted Local Time Offset, Daylight Savings Time, DST (start/stop for month/day/hour) from Real
Time Clock menu
5-
5-40
Add
Added submenus Precision Time Protocol, SNTP Protocol, and Local Time and Synchronizing
Source settings to Real Time Clock menu
5-
5-42
Add
Added new Precision Time Protocol (1588) menu and setting descriptions
5-
5-
Update
Changed Communication to Real Time Clock in SNTP protocol settings path. Moved SNTP
Protocol menu and settings descriptions to Real Time Clock subsection
5-37
5-
Delete
Deleted section k) SNTP Protocol and the settings descriptions
5-
5-45
Add
Added new section for Local Time menu settings and settings description
5-
5-54
Add
Added new PTP Fail menu item to the User-Programmable Self Tests menu
5-
5-
Add
Added PTP Failure and CLOCK UNSYNCHRONIZED to Flexlogic Operands table
5-94
5-94
Update
Updated PMU main menu to add aggregator and control block menu items
5-
5-94
Add
Added UR Synchrophasor Implementation of IEC61850-90-5 to the PMU software option
description
5-94
5-94
Update
Updated Figure: Complete Synchrophasor Implementation
5-
5-95
Add
Added Figure: N60 Support For Four Logical Device PMU
5-97
5-95
Update
Updated Table: Implementation By Model Number
5-
5-96
Add
Added Figure: Logical Nodes Supported In Each Logical Device
5-
5-97
Add
Added Figure: Data Set Created From User Selected Internal Items
5-
5-98
Add
Added Figure: Example Of Aggregator Data Sets
5-
5-98
Add
Added Figure: CFG-2 Based Configuration Solution
5-
5-98
Add
Added examples for a syncrophasor dataset and the creation of different datasets
5-
5-98
Add
Added example for a CFG-2 based configuration
5-100
5-100
Update
Updated PMU 1 basic configuration menu to add 37.118 and 90-5 configuration settings
submenus
5-
5-101
Add
Added PMU 1 configuration menus for 37.118 and 90-5 with settings descriptions
5-
5-101
Update
Changed PMU 1 Function setting description
5-
5-111
Add
Added PMU AGGR 1 configuration menu and setting descriptions
5-
5-111
Add
Added new aggregators section with PMU 1 aggregators menu and setting descriptions
5-111
5-111
Update
Updated PMU 1 aggregators menu to include 37.118 and 90-5 aggregator configuration
submenus
5-
5-112
Add
Added 90-5 AGGR 1 configuration menu and setting descriptions
5-
5-113
Add
Added Table 5-11 # Of ASDUs
5-
5-113
Add
Added new control block section with IEC 90-5 MSVCB configuration menu and setting
descriptions
5-
5-137
Update
Added row for DeltaTime to Table 5-: FlexElement Base Units
5-141
5-141
Update
Updated Settings Group menu in section 5.6.2 to include Breaker Failure menu item
5-
5-195
Added
Added Breaker Failure menu and settings descriptions as section 5.6.12
5-272
5-272
Delete
Deleted section 5.8.5c Remote Devices: ID of Device for Receiving GSSE/GOOSE Messages,
meaning the Settings > Input/Outputs > Remote Devices settings
5-
5-296
Add
Added new CyberSentry security section and main menu, local passwords, session settings,
restore defaults, and supervisory subsections to Chapter 5
Table G–7: MAJOR UPDATES FOR G60 MANUAL REVISION Y1 (Sheet 2 of 3)
PAGE
(X2)
PAGE
(Y1)
CHANGE
DESCRIPTION
Summary of Contents for Multilin g60
Page 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Page 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...