B-90
G60 Generator Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
F237
ENUMERATION: REAL TIME CLOCK MONTH (FOR EXAMPLE,
DAYLIGHT SAVINGS TIME)
F238
ENUMERATION: REAL TIME CLOCK DAY (FOR EXAMPLE,
DAYLIGHT SAVINGS TIME)
F239
ENUMERATION: REAL TIME CLOCK DAYLIGHT SAVINGS
TIME START DAY INSTANCE
F240
ENUMERATION: V/HZ CURVES
0 = Definite Time, 1 = Inverse A, 2 = Inverse B, 3 = Inverse C,
4 = FlexCurve A, 5 = FlexCurve B, 6 = FlexCurve C,
7 = FlexCurve D
F243
ENUMERATION: FIELD UNIT TYPE
0 = CC-05, 1 = CV-05, 2 = CC-01, 3 = CV-01
F244
ENUMERATION: FIELD UNIT PROCESS CARD PORT
0 = H4a, 1 = H4b, 2 = H3a, 3 = H3b, 4 = H2a, 5 = H2b, 6 = H1a,
7 = H1b
F245
ENUMERATION: TEST MODE FUNCTION
x F246
ENUMERATION: BRICK TRANSDUCER RANGE
169 GGIO3.ST.UIntIn2.stVal
170 GGIO3.ST.UIntIn3.q
171 GGIO3.ST.UIntIn3.stVal
172 GGIO3.ST.UIntIn4.q
173 GGIO3.ST.UIntIn4.stVal
174 GGIO3.ST.UIntIn5.q
175 GGIO3.ST.UIntIn5.stVal
176 GGIO3.ST.UIntIn6.q
177 GGIO3.ST.UIntIn6.stVal
178 GGIO3.ST.UIntIn7.q
179 GGIO3.ST.UIntIn7.stVal
180 GGIO3.ST.UIntIn8.q
181 GGIO3.ST.UIntIn8.stVal
182 GGIO3.ST.UIntIn9.q
183 GGIO3.ST.UIntIn9.stVal
184 GGIO3.ST.UIntIn10.q
185 GGIO3.ST.UIntIn10.stVal
186 GGIO3.ST.UIntIn11.q
187 GGIO3.ST.UIntIn11.stVal
188 GGIO3.ST.UIntIn12.q
189 GGIO3.ST.UIntIn12.stVal
190 GGIO3.ST.UIntIn13.q
191 GGIO3.ST.UIntIn13.stVal
192 GGIO3.ST.UIntIn14.q
193 GGIO3.ST.UIntIn14.stVal
194 GGIO3.ST.UIntIn15.q
195 GGIO3.ST.UIntIn15.stVal
196 GGIO3.ST.UIntIn16.q
197 GGIO3.ST.UIntIn16.stVal
Value
Month
0
January
1
February
2
March
3
April
4
May
5
June
6
July
7
August
8
September
9
October
10
November
11
December
Value
IEC 61850 GOOSE Rx dataset
item
Value
Day
0
Sunday
1
Monday
2
Tuesday
3
Wednesday
4
Thursday
5
Friday
6
Saturday
Value
Instance
0
First
1
Second
2
Third
3
Fourth
4
Last
Value
Function
0
Disabled
1
Isolated
2
Forcible
Value
Description
0
-5...5V
Summary of Contents for Multilin g60
Page 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Page 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...