GE Multilin
G60 Generator Protection System
A-7
APPENDIX A
A.1 PARAMETER LISTS
A
7256
SRC 3 PF
---
Source 3 three-phase power factor
7257
SRC 3 Phase A PF
---
Source 3 phase A power factor
7258
SRC 3 Phase B PF
---
Source 3 phase B power factor
7259
SRC 3 Phase C PF
---
Source 3 phase C power factor
7264
SRC 4 P
Watts
Source 4 three-phase real power
7266
SRC 4 Pa
Watts
Source 4 phase A real power
7268
SRC 4 Pb
Watts
Source 4 phase B real power
7270
SRC 4 Pc
Watts
Source 4 phase C real power
7272
SRC 4 Q
Vars
Source 4 three-phase reactive power
7274
SRC 4 Qa
Vars
Source 4 phase A reactive power
7276
SRC 4 Qb
Vars
Source 4 phase B reactive power
7278
SRC 4 Qc
Vars
Source 4 phase C reactive power
7280
SRC 4 S
VA
Source 4 three-phase apparent power
7282
SRC 4 Sa
VA
Source 4 phase A apparent power
7284
SRC 4 Sb
VA
Source 4 phase B apparent power
7286
SRC 4 Sc
VA
Source 4 phase C apparent power
7288
SRC 4 PF
---
Source 4 three-phase power factor
7289
SRC 4 Phase A PF
---
Source 4 phase A power factor
7290
SRC 4 Phase B PF
---
Source 4 phase B power factor
7291
SRC 4 Phase C PF
---
Source 4 phase C power factor
7552
SRC 1 Frequency
Hz
Source 1 frequency
7554
SRC 2 Frequency
Hz
Source 2 frequency
7556
SRC 3 Frequency
Hz
Source 3 frequency
7558
SRC 4 Frequency
Hz
Source 4 frequency
8064
SRC 1 Va THD
%
Source 1 phase A voltage total harmonic distortion (THD)
8065
SRC 1 Va Harm[0]
%
Source 1 phase A voltage second harmonic
8066
SRC 1 Va Harm[1]
%
Source 1 phase A voltage third harmonic
8067
SRC 1 Va Harm[2]
%
Source 1 phase A voltage fourth harmonic
8068
SRC 1 Va Harm[3]
%
Source 1 phase A voltage fifth harmonic
8069
SRC 1 Va Harm[4]
%
Source 1 phase A voltage sixth harmonic
8070
SRC 1 Va Harm[5]
%
Source 1 phase A voltage seventh harmonic
8071
SRC 1 Va Harm[6]
%
Source 1 phase A voltage eighth harmonic
8072
SRC 1 Va Harm[7]
%
Source 1 phase A voltage ninth harmonic
8073
SRC 1 Va Harm[8]
%
Source 1 phase A voltage tenth harmonic
8074
SRC 1 Va Harm[9]
%
Source 1 phase A voltage eleventh harmonic
8075
SRC 1 Va Harm[10]
%
Source 1 phase A voltage twelfth harmonic
8076
SRC 1 Va Harm[11]
%
Source 1 phase A voltage thirteenth harmonic
8077
SRC 1 Va Harm[12]
%
Source 1 phase A voltage fourteenth harmonic
8078
SRC 1 Va Harm[13]
%
Source 1 phase A voltage fifteenth harmonic
8079
SRC 1 Va Harm[14]
%
Source 1 phase A voltage sixteenth harmonic
8080
SRC 1 Va Harm[15]
%
Source 1 phase A voltage seventeenth harmonic
8081
SRC 1 Va Harm[16]
%
Source 1 phase A voltage eighteenth harmonic
8082
SRC 1 Va Harm[17]
%
Source 1 phase A voltage nineteenth harmonic
8083
SRC 1 Va Harm[18]
%
Source 1 phase A voltage twentieth harmonic
8084
SRC 1 Va Harm[19]
%
Source 1 phase A voltage twenty-first harmonic
8085
SRC 1 Va Harm[20]
%
Source 1 phase A voltage twenty-second harmonic
8086
SRC 1 Va Harm[21]
%
Source 1 phase A voltage twenty-third harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 7 of 27)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for Multilin g60
Page 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Page 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...