A-6
G60 Generator Protection System
GE Multilin
A.1 PARAMETER LISTS
APPENDIX A
A
6888
SRC 4 V_1 Angle
Degrees
Source 4 positive-sequence voltage angle
6889
SRC 4 V_2 Mag
Volts
Source 4 negative-sequence voltage magnitude
6891
SRC 4 V_2 Angle
Degrees
Source 4 negative-sequence voltage angle
7168
SRC 1 P
Watts
Source 1 three-phase real power
7170
SRC 1 Pa
Watts
Source 1 phase A real power
7172
SRC 1 Pb
Watts
Source 1 phase B real power
7174
SRC 1 Pc
Watts
Source 1 phase C real power
7176
SRC 1 Q
Vars
Source 1 three-phase reactive power
7178
SRC 1 Qa
Vars
Source 1 phase A reactive power
7180
SRC 1 Qb
Vars
Source 1 phase B reactive power
7182
SRC 1 Qc
Vars
Source 1 phase C reactive power
7184
SRC 1 S
VA
Source 1 three-phase apparent power
7186
SRC 1 Sa
VA
Source 1 phase A apparent power
7188
SRC 1 Sb
VA
Source 1 phase B apparent power
7190
SRC 1 Sc
VA
Source 1 phase C apparent power
7192
SRC 1 PF
---
Source 1 three-phase power factor
7193
SRC 1 Phase A PF
---
Source 1 phase A power factor
7194
SRC 1 Phase B PF
---
Source 1 phase B power factor
7195
SRC 1 Phase C PF
---
Source 1 phase C power factor
7200
SRC 2 P
Watts
Source 2 three-phase real power
7202
SRC 2 Pa
Watts
Source 2 phase A real power
7204
SRC 2 Pb
Watts
Source 2 phase B real power
7206
SRC 2 Pc
Watts
Source 2 phase C real power
7208
SRC 2 Q
Vars
Source 2 three-phase reactive power
7210
SRC 2 Qa
Vars
Source 2 phase A reactive power
7212
SRC 2 Qb
Vars
Source 2 phase B reactive power
7214
SRC 2 Qc
Vars
Source 2 phase C reactive power
7216
SRC 2 S
VA
Source 2 three-phase apparent power
7218
SRC 2 Sa
VA
Source 2 phase A apparent power
7220
SRC 2 Sb
VA
Source 2 phase B apparent power
7222
SRC 2 Sc
VA
Source 2 phase C apparent power
7224
SRC 2 PF
---
Source 2 three-phase power factor
7225
SRC 2 Phase A PF
---
Source 2 phase A power factor
7226
SRC 2 Phase B PF
---
Source 2 phase B power factor
7227
SRC 2 Phase C PF
---
Source 2 phase C power factor
7232
SRC 3 P
Watts
Source 3 three-phase real power
7234
SRC 3 Pa
Watts
Source 3 phase A real power
7236
SRC 3 Pb
Watts
Source 3 phase B real power
7238
SRC 3 Pc
Watts
Source 3 phase C real power
7240
SRC 3 Q
Vars
Source 3 three-phase reactive power
7242
SRC 3 Qa
Vars
Source 3 phase A reactive power
7244
SRC 3 Qb
Vars
Source 3 phase B reactive power
7246
SRC 3 Qc
Vars
Source 3 phase C reactive power
7248
SRC 3 S
VA
Source 3 three-phase apparent power
7250
SRC 3 Sa
VA
Source 3 phase A apparent power
7252
SRC 3 Sb
VA
Source 3 phase B apparent power
7254
SRC 3 Sc
VA
Source 3 phase C apparent power
Table A–1: FLEXANALOG DATA ITEMS (Sheet 6 of 27)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for Multilin g60
Page 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Page 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...