GE Multilin
G60 Generator Protection System
B-43
APPENDIX B
B.4 MEMORY MAPPING
B
74B5
Disconnect Switch 1 Phase C Closed
0 to 4294967295
---
1
F300
0
74B7
Disconnect Switch 1 Phase C Opened
0 to 4294967295
---
1
F300
0
74B9
Disconnect Switch 1 Operate Time
0 to 65.535
s
0.001
F001
70
74BA
Disconnect Switch 1 Alarm Delay
0 to 65.535
s
0.001
F003
0
74BC
Disconnect Switch 1 Events
0 to 1
---
1
F102
0 (Disabled)
74BD
Reserved (2 items)
---
---
---
F001
0
74BF
...Repeated for Disconnect Switch 2
74DE
...Repeated for Disconnect Switch 3
74FD
...Repeated for Disconnect Switch 4
751C
...Repeated for Disconnect Switch 5
753B
...Repeated for Disconnect Switch 6
755A
...Repeated for Disconnect Switch 7
7579
...Repeated for Disconnect Switch 8
7598
...Repeated for Disconnect Switch 9
75B7
...Repeated for Disconnect Switch 10
75D6
...Repeated for Disconnect Switch 11
75F5
...Repeated for Disconnect Switch 12
7614
...Repeated for Disconnect Switch 13
7633
...Repeated for Disconnect Switch 14
7652
...Repeated for Disconnect Switch 15
Thermal Overload Protection (Read/Write Settings) (2 modules)
7788
Thermal Protection 1 Function
0 to 1
---
1
F102
0 (Disabled)
7789
Thermal Protection 1 Source
0 to 5
---
1
F167
0 (SRC 1)
778A
Thermal Protection 1 Base Current
0.2 to 3
pu
0.01
F001
80
778B
Thermal Protection 1 K Factor
1 to 1.2
---
0.05
F001
110
778C
Thermal Protection 1 Trip Time Constant
0 to 1000
min.
1
F001
45
778D
Thermal Protection 1 Reset Time Constant
0 to 1000
min.
1
F001
45
778E
Thermal Protection 1 Minimum Reset Time
0 to 1000
min.
1
F001
20
778F
Thermal Protection 1 Reset
0 to 4294967295
---
1
F300
0
7791
Thermal Protection 1 Block
0 to 4294967295
---
1
F300
0
7793
Thermal Protection 1 Target
0 to 2
---
1
F109
0 (Self-reset)
7794
Thermal Protection 1 Events
0 to 1
---
1
F102
0 (Disabled)
7795
Reserved (2 items)
---
---
---
F001
0
7797
Repeated for Thermal Protection 2
Ohm Inputs (Read/Write Setting) (2 modules)
77F8
Ohm Inputs 1 Function
0 to 1
---
1
F102
0 (Disabled)
77F9
Ohm Inputs 1 ID
---
---
---
F205
"Ohm Ip 1 "
77FF
Ohm Inputs 1 Reserved (9 items)
0 to 65535
---
1
F001
0
7808
...Repeated for Ohm Inputs 2
Phasor Measurement Unit Recorder Config Counter Command (Read/Write Command)
781A
PMU 1 Recorder Clear Config Counter
0 to 1
---
1
F126
0 (No)
Phasor Measurement Unit Power Trigger (Read/Write Setting)
7820
PMU 1 Power Trigger Function
0 to 1
---
1
F102
0 (Disabled)
7821
PMU 1 Power Trigger Active
0.25 to 3
pu
0.001
F001
1250
7822
PMU 1 Power Trigger Reactive
0.25 to 3
pu
0.001
F001
1250
7823
PMU 1 Power Trigger Apparent
0.25 to 3
pu
0.001
F001
1250
7824
PMU 1 Power Trigger Pickup Time
0 to 600
s
0.01
F001
10
7825
PMU 1 Power Trigger Dropout Time
0 to 600
s
0.01
F001
100
7826
PMU 1 Power Trigger Block (3 items)
0 to 4294967295
---
1
F300
0
782C
PMU 1 Power Trigger Target
0 to 2
---
1
F109
0 (Self-reset)
782D
PMU 1 Power Trigger Events
0 to 1
---
1
F102
0 (Disabled)
Phasor Measurement Unit Voltage Trigger (Read/Write Setting)
7858
PMU 1 Voltage Trigger Function
0 to 1
---
1
F102
0 (Disabled)
7859
PMU 1 Voltage Trigger Low Voltage
0.25 to 1.25
pu
0.001
F001
800
Table B–10: MODBUS MEMORY MAP (Sheet 35 of 68)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for Multilin g60
Page 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Page 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...