MHT258a (Engl.)
2-9
(3) Slim type motor (0.05 to 0.2 [kW]) for 100 [V] class input voltage of amplifier
(a) Basic design
Type
GYS
□□□
DC1-S 500
101
201
Rated output
[kW] 0.05
0.1
0.2
Rated torque (*4)
[N
•
m] 0.159
0.318
0.637
Rated
3000
Speed
[r/min]
Max.
5000
Breakdown (max.) torque (*3)
[N
•
m] 0.478
0.955
1.91/2.87
Moment of inertia of motor rotor (
×
10
-3
) J[kg
•
m
2
] 0.00341
0.00517
0.0137
Rated
0.85
1.5
2.7
Current
[A]
Max. (*3)
2.55
4.5
8.1/12.1
Winding insulation class
B
Operation duty type
Continuous
Degree of enclosure protection
Totally enclosed, IP55 except for shaft sealing
Motor power
Electrical connection
terminals
Encoder detector
With 0.3 m flexible leads and connectors
Temp. detection
Without providing
Type of construction (mounting)
IMB5, IMV1, IMV3, flange-mounted
Shaft extension
Cylindrical extension with key
Final color for external non-machined surface
Munsell N1.5
Encoder detector
16-bit serial encoder
Vibration level, peak to peak amplitude
5 micrometers
Install location
For indoors, 1000[m] and below of site-altitude
Ambient climatic conditions
Temperature :
−
10 to +40 [°C], humidity : 90 [%] RH max. (free from condensation)
Acceleration vibration, acceptable (max.)
4.9 [m/s
2
]
Mass (weight)
[kg] 0.45
0.55
1.2
(*1) 15 micrometers for over the rated speed.
(*2) Direction of gear-output-shaft rotation is CCW (counter-clockwise), when motor shaft rotates forward(*).
The direction is viewed from a point facing the drive-end of motor.
(*3) Breakdown (max.) torque and maximum current values are selected in accordance with the following paired combination of amplifier
and motor types.
Lower value/higher value
:
When the same output [kW] rating of amplifier and motor/when amplifier size is one step larger than the motor frame No. size
corresponding with amplifier.
Refer to 2.3.
(*4) Rated torque are continuous operating torque , on condition that motors are mounted heat sink which size are bellow table.
Motor type
Heat sink size [mm]
GYS500DC1-S8
200
×
200
×
6
GYS101DC1-S6
200
×
200
×
6
GYS201DC1-S6
250
×
250
×
6
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...