MHT258a (Engl.)
4-22
(6) Positioning module : NC1F-VP1
Typical connection with a positioning module for MICREX-F F70 (Fuji
’
s PLC) is shown below.
Linear positioning can be applied. The pulse train of NC1F-VP1 is open collector output.
The output form setting at our shop before shipping is forward and reverse pulses.
•
If MON output is on, the automatic start signal is not validated.
•
MOFF at the same scan as when MON is on is not validated.
A6
A7
B7
+12 to 24[V]
‑12 to 24[V]
COM
A10
B10
+5[V]
+5[V]
A9
A8
B8
A11
B11
Positioning end
Ready
COM
A12
B12
Reverse pulse
COM
Forward pulse
COM
B4
B9
External marker
COM
A4
B3
A3
A2
B2
Origin limit switch
External interrupt
Forced stop
+OT
‑OT
A1
B1
+12 to 24[V]
+12 to 24[V]
M24
P24
M24
P24
①
②
③
④
⑤
⑥
+24[V]
power supply
NC1F‑VP1
(continue to the next page)