7-20
MHT258a (Engl.)
(3) Position preset (
)
The current position of motor can be preset. The following alarm detected can be reset.
・
ABS data loss
・
Absolute data overflow
The current position is set by basic para. 80.
Position preset cannot be made while the motor is rotating.
(4) Alarm reset (
)
Resets the alarm detected by the amplifier.
(5) Initializing the history (
)
Deletes the history of alarms detected held by the amplifier.
This history can be monitored by a sequence mode of [
].
The alarm history is held even after turning off power.
(6) Initializing the paras. (
)
Initializes the basic paras. and system paras.
* After initializing, be sure to turn off and on power.
ENT (1s or more)
ESC
ENT
ESC
ENT
ENT (1s or more)
ESC
ENT
ESC
(Initializing complete)
(Initializing complete)
ENT
ENT (1s or more)
ESC
ESC
ESC
ENT (1s or more)
ESC
Preset end
ESC
ENT