(vi) Calculation of actual torque (Trms)
Actual torque can be calculated by the following formula.
T
=
((0.86
0.05 2) + (0.03
rms
2
2
×
×
×
× =
0 05
1
0 5
0 38
. ))
.
.
[N
・
m]
Since the rated torque of 0.2[kW] motor is 0.637 [N
・
m], a relation of “actual torque < rated torque “ is satisfied. Therefore, the temporarily
selected motor is actually applicable.
(vii) Examination of braking resistor
In the above torque pattern, the hatched area corresponds to the regenerative braking mode. Braking power is as follow.
P
1
= 0.105
×
T
AC
×
N
×
(1/2) = 0.105
×
0.86
×
3000
×
(1/2) = 135 [W]
From the above result, mean braking power per cycle is :
P =
135 0.05
0.5
×
=
14 [W]
(4) Determination of external braking resistor
Because of the braking resistor is not built-in the 0.2[kW] motor, requiring of external braking resistor provision is reviewed as follows :
(a) Energy (E
G
) on the mechanical equipment system during deceleration
E
1
2
G
=
+
=
×
+
×
×
×
é
ë
ê
ù
û
ú
=
−
−
(
) (
/
)
( .
.
)
. [ ]
J
J
N
J
M
L
・ π
π
2
60
1
2
0 0216 10
0 11 10
2
3000
60
6 5
2
3
3
2
(b) Consumption energy (E
L
) due to load torque
E
L
= ( 2
π
/ 60 )
×
T
L
×
N
×
t
DC
×
( 1/2 )
= ( 2
π
/ 60 )
×
0.03
×
3000
×
0.05
×
( 1/2 ) = 0.24 [ J ]
(c) Consumption energy (E
M
) in motor winding
E
M
= 3
×
( R
×
I
2
)
×
t
DC
= 3
×
R
×
(( T
DC
/ T
R
×
I
R
)
2
)
×
t
DC
= 3
×
2
×
(( 0.86 / 0.637
×
1.5 )
2
)
×
0.05 = 1.2 [ J ]
(d) Absorbing energy (E
S
) of motor
E
1
2
S
=
=
×
×
−
×
=
−
CV
J
2
6
2
1
2
2
1
2
660 10
370
200 2
18 7
(
) (
(
) )
. [ ]
Where,
R : Phase resistance of stator winding of GYC201 type motor is 2[
Ω
], at room temperature
V : Power supply voltage 200 [ V ]
C : DC intermediate capacity of RYS201 amplifier 660[
μ
F]
(e) Consumption and absorbing energies ( E
L
+ E
M
+ E
S
) is 20 [ J ], which is larger than the energy on the mechanical equipment
system ( E
G
= 6.5 [ J ]). Therefore, external braking resistor provision is not required in this example.
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...