MHT258a (Engl.)
5-39
■
Related items
・
Parameter setting
Origin return action depends on basic parameter 71 to 79 setting.
Para.
Name
Setting range
Initial value
Change
71
Origin return pattern
1 : Pattern 1, 2 : Pattern 2
3 : Pattern 3, 4 : Pattern 4
1
Power
72
Origin return direction
0 : Positive,
1 : Negative direction
0
Power
73
Z-phase valid/invalid
0 : Valid
1 : Invalid
0
Power
74
Origin LS logic
0 : NO contact
1 : NC contact
0
Always
75
Origin return speed
0.01 to Max. speed [r/min]
(in 0.01 steps)
500.00
Always
76
Origin detection creep speed
0.01 to Max. speed [r/min]
(in 0.01 steps)
50.00
Always
77
Origin shift quantity
1 to 2,000,000 (in increments of 1)
[x unit q’ty]
1000
Always
78
Origin return reversing quantity
1 to 79,999,999 (in increments of 1)
[x unit q’ty]
0
Always
79
Origin return position
1 to
±
79,999,999 (in increments of 1)
[x unit q’ty]
0
Always
*After changing basic para. 71 to 73, power supply need be turned on again.
・
Origin return action
At the ON edge of origin return [ORG] signal, the following operations are automatically carried out.
(a) At the ON edge of [ORG] signal, motor starts at “Origin return speed” (basic para. 75) in “Origin return direction” (basic para. 72)
(b) When the [LS] signal turns from off to on, speed is reduced to “Origin detection creep speed” (basic para. 76). While [LS] on, motor runs
at constant speed.
(c) The first encoder Z-phase signal is detected following the transition of [LS] signal from OFF to ON.
(d) The motor stops after rotating by “Origin shift q’ty” (basic para. 77) from the detection of Z-phase signal.
(e) The [PSET] signal turns on with the stopped position as “Origin return position” (basic para. 79). “Origin return complete” signal as the
control output signal turns on.
An origin return action can be selected out of 4 patterns in the “Origin return pattern” (basic para. 71).
Also, with the Z-phase input invalid (1) selected in the “Z-phase valid/invalid” (basic para. 73), motor can be stopped after running by the
“Origin shift q’ty” (basic para. 77) from the ON to OFF edge of [LS] signal.
The ON/OFF status of [LS] signal can be inverted using “Origin LS logic” (basic para. 74)
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...