MHT258a (Engl.)
5-51
■
Interface
■
Parameter setting
To allocate the fixed/passing point 1 signal to the control output terminal, set (17) to the system para. Set (18) for the fixed/passing point 2.
■
Related items
・
Selection of output form
Output form can be set by basic para. 62 to 65.
Basic parameter 62 to 65
Para.
Name
Setting range
Initial value
Change
62
Fixed/passing point detection
0 : Fixed point
1 : Passing point off
à
on
2 : Passing point on
à
off
0
Always
63
Fixed/passing point detection position 1
0 to
±
79,999,999 (in increments of 1)
[x unit q’ty]
0
Always
64
Fixed/passing point detection position 2
0 to
±
79,999,999 (in increments of 1)
[x unit q’ty]
0
Always
65
Fixed point detection range (zone)
0 to
±
79,999,999 (in increments of 1)
[x unit q’ty]
100
Always
・
Valid or invalid of position detection function
Position detection function such as fixed/passing point 1 can be effective after origin return end.
Basic parameter 67
Para.
Name
Setting range
Initial value
Change
67
Position detection function valid/invalid
0 : Valid after origin return 1 : Always
0
Always
5.7.6 Override
This function changes the current motor speed.
While
“
override effective
”
(43) signal is turned on, the motor speed is variable by a scale factor specified by
“
override 1/2/4/8
”
up to 1.5
times the current speed.
Weighting of scale factor corresponding to override 1/2/4/8 can be changed by basic para.
This function is effective for any rotation command except for torque control, pulse train input (pulse train ratio 1 or 2).
This function will not be effective after the ON edge of interrupt input in interrupt positioning.
■
Interface
Fixed/passing point 1 (17)
Fixed/passing point 2 (18)
ON/OFF : Automatically turns on or off according to the current position
Override effective (43)
Override 1 (44)
Override 2 (45)
Override 4 (46)
Override 8 (47)
+24V
P24
M24
2.2k
+24V
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...