3-6
MHT258a (Engl.)
Compliance with EC directives
• This product should be installed in the electrical cabinet.
• Servo driver is used under the "pollution degree 2" environment as specified in IEC664.
(3) Peripheral equipment
(a) Power supply
The amplifier is used under the "over voltage category II" environment as specified in IEC 664.
The power input unit uses a reinforced isolation transformer based on IEC/EN standards.
A 3-phase, star-connected transformer should be used without regard to single-phase and 3-phase models. The transformer should be
grounded at the neutral point. The phase (line to earth) voltage must not exceed 120[V].
(2)
(1)
(3)
For the interface power source, use a 24[V] DC power source with reinforced isolation type input and output.
(b) Power filter
Regarding the EMI terminal disturbance voltage, a power filter is required.
Input voltage class
[V]
100
200
Amplifier output
[kW]
0.05 to 0.2
0.05 to 0.4
0.75 to 1
1.5
2
3
4
5
Power filter type
HF
□□□□
A-TM
3005
3010
3015
3020
3030
3040
3050
Current
[A]
5
10
15
20
30
40
50
Voltage
250[V] AC
Leakage current
1.5[mA] max. at 250[V] AC, 60[Hz]
(5)
(6)
(7)
(8)
(9)
(1)
(3)
(2)
(4)
(1) Amplifier
(2) Reinforced isolation transformer
(3) 230[V] / 3 = 133[V]
(1) Power supply
source
(2) Amplifier
(3) Motor
(4) Control panel
(5) Reinforced
isolation
transformer
(6) Earth leakage
circuit breaker
(7) Auto circuit
breaker
(8) Power filter
(9) 24[V] DC power
source
Summary of Contents for Faldic-a Series
Page 1: ...RYS V Type User s Manual MHT258a Engl...
Page 55: ...3 28 MHT258a Engl 2 RYS amplifier a 0 03 to 0 2 kW 5 5 150 0 5 0 5 53 60 160 130...
Page 56: ...3 29 MHT258a Engl b 0 4 kW 160 130 60 80 53 150 0 5 0 5 5 5...
Page 57: ...3 30 MHT258a Engl c 0 75 kW 130 160 60 100 54 39 0 5 0 5 150 0 5 0 5 5 5...
Page 58: ...3 31 MHT258a Engl d 1 to 1 5 kW 160 130 60 115 54 54 0 5 0 5 150 0 5 0 5 5 5 Cooling fan...